Quick Link
Quick Contact
Address
Room 13G, No. 888 Wanhangu Road, Jing'an District, Shanghai, China
Tel
86--13912788181
Our Newsletter
Subscribe to our newsletter for discounts and more.
Our vertical sump pump is designed for transferring corrosive liquids in industrial waste gas treatment, wet scrubbers, acid washing systems, and chemical processing facilities. With an injection-moulded FRPP or PVDF pump body, it provides corrosion resistance for many acid and alkali applications when the material is compatible with the actual liquid concentration and temperature.
The vertical liquid-sump installation places the pump's lower section directly into the collection tank, reducing the need for a separate suction pipeline and external priming. A dry shaft seal is designed to tolerate short periods of dry running, while an additional oil seal at the motor end helps prevent corrosive vapour from entering the motor bearing area.
Available in 1–10 HP models, this chemical vertical sump pump offers different flow and head options for scrubber circulation and spray systems. SUS304, SUS316L, or titanium shaft options and explosion-proof motors are available according to project requirements.
Industrial scrubber and chemical sump pumps can experience premature failure under demanding operating conditions:
Chemical corrosion: Ordinary metal pump bodies may corrode when exposed to incompatible acids, alkalis, or chemical solutions.
Seal damage: Liquid leakage or unsuitable sealing arrangements can cause maintenance problems and equipment downtime.
Accidental low liquid level: When the sump level drops, conventional pumps may suffer damage from dry running.
Corrosive vapour: Acid vapour entering the motor bearing area can accelerate corrosion and shorten bearing service life.
Impeller blockage: Suspended particles and deposits may obstruct the inlet screen or impeller, reducing flow and spray pressure.
Difficult installation: External suction arrangements may require additional piping, priming, and floor space.
The FRPP and PVDF vertical sump pump is designed for corrosive liquid transfer in industrial treatment systems. Its non-metallic pump body helps reduce corrosion risks in compatible chemical applications. FRPP is commonly considered for many general acid and alkali services, while PVDF may be preferred for selected more demanding chemical or temperature conditions. Final selection must be checked against chemical concentration, temperature, and compatibility data.
The vertical sump-mounted design places the pump inlet below the liquid surface, eliminating the need for a conventional external suction line and separate priming operation. Its dry shaft seal can tolerate short periods of dry running, but continuous operation without sufficient liquid must be avoided. An oil seal at the motor end helps protect the bearing area from corrosive vapour.
A bottom inlet screen helps prevent larger particles from entering the pump. Optional SUS304, SUS316L, or titanium shaft configurations and explosion-proof motors are available for different operating environments.
| Parameter | Specification |
|---|---|
| Product Type | Vertical Sump Pump |
| Pump Body Material | FRPP or PVDF |
| Shaft Material | SUS304, SUS316L, or Titanium |
| Available Power | 1–10 HP (0.75–7.5 kW) |
| Frequency | 50 / 60 Hz reference data |
| Connection Range | 50 × 32 mm to 65 × 50 mm |
| Installation | Vertical, sump-mounted |
| Shaft Seal | Dry shaft seal, short dry-running tolerance |
| Motor Option | Explosion-proof motor available |
| Sump Version | 300 mm or 400 mm; confirm model availability |
Model Reference Data at 50 Hz
| Model | Power (HP / kW) | Inlet × Outlet (mm) | Head (m) | Flow (L/min) | Weight (kg) |
|---|---|---|---|---|---|
| PTH-32SK-1 | 1 / 0.75 | 50 × 32 | 13 | 160 | 20 |
| PTH-40SK-2 | 2 / 1.5 | 50 × 40 | 24 | 260 | 25 |
| PTH-40SK-3 | 3 / 2.2 | 50 × 40 | 26 | 350 | 29 |
| PTH-50SK-5 | 5 / 3.75 | 50 × 50 | 28 | 520 | 32 |
| PTH-50SK-7.5 | 7.5 / 5.5 | 65 × 50 | 31 | 640 | 46 |
| PTH-50SK-10 | 10 / 7.5 | 65 × 50 | 36 | 700 | 73 |
Flow and head figures are reference specifications. Confirm the operating point using the manufacturer's pump performance curve.
This corrosion-resistant vertical pump is suitable for:
Wet scrubber systems: Circulating washing liquid in industrial exhaust gas treatment equipment.
FGD and desulfurization auxiliary systems: Transferring compatible process liquids in collection sumps.
Acid washing towers: Pumping compatible acid or alkali solutions.
Chemical processing: Liquid transfer in chemical production and treatment facilities.
Electroplating plants: Moving compatible process liquids and wastewater.
Wastewater treatment: Sump transfer and circulation in suitable industrial treatment processes.
Typical buyers include scrubber manufacturers, environmental engineering contractors, chemical plants, electroplating factories, distributors, and industrial maintenance teams.
The motor drives the impeller through a vertical shaft. The lower pump section is immersed in the sump, allowing liquid to enter through the bottom inlet screen. The rotating impeller transfers energy to the liquid and delivers it through the discharge outlet to the connected pipeline or spray system.
The submerged inlet avoids the need for a conventional suction lift and separate priming. The dry shaft seal is designed to tolerate short periods of dry running, while the motor-end oil seal helps limit corrosive vapour entering the bearing area.
Check chemical compatibility: Provide the liquid name, concentration, temperature, and any suspended solids before selecting FRPP or PVDF.
Calculate flow and head: Determine the required circulation flow, pipeline resistance, elevation, and spray nozzle pressure.
Check the pump curve: Select a model whose performance curve covers the required operating point.
Confirm installation length: Check sump depth, liquid level, and whether the 300 mm or 400 mm version is required.
Select shaft and fastener materials: Choose SUS304, SUS316L, titanium, or plastic components according to the liquid conditions.
Confirm motor requirements: Specify standard or explosion-proof motor requirements based on the site's hazardous area classification.
Send us your liquid details, required flow, total head, sump depth, power supply, and installation requirements for model selection and quotation.
Q1: Can a vertical sump pump handle acid and alkali solutions?
Yes, FRPP and PVDF versions are available for many acid and alkali applications. Confirm chemical concentration and temperature before selecting the pump material.
Q2: Can this pump run dry?
The dry shaft seal tolerates short periods of dry running, but this does not mean continuous dry operation is permitted. Maintain the required liquid level.
Q3: What is the difference between FRPP and PVDF?
Both offer chemical resistance, but their compatibility and temperature limits differ. Select according to the actual chemical, concentration, and operating temperature.
Q4: Is an explosion-proof motor available?
Yes. Explosion-proof motor options can be specified. Confirm the hazardous area classification and applicable motor requirements before ordering.
Q5: How do I select the correct pump for a scrubber tower?
Calculate the required circulation flow and total head, including pipeline losses and spray nozzle pressure. Then verify the operating point against the pump performance curve.
Q6: What information is needed for a quotation?
Provide the liquid composition, concentration, temperature, required flow, total head, sump depth, connection size, power supply, and quantity.