Static Grounding Alarm Fixed Mobile Stainless Steel Housing

Place of Origin: China
Brand Name: HUAQIN; Custom
Certification: ISO / RoHS / SGS
Model Number: PX-SGA-P
Minimum Order Quantity: 20
Price: Determined according to specifications and models
Packaging Details: Carton packaging
Delivery Time: 1. In‑stock items: Shipment within 2‑3 working days; 2. Custom‑made items: Subject to the degree of customization
Payment Terms: T/T
Supply Ability: Stable daily and monthly output, with support for OEM/ODM customization services.
Inquiry Now
Get A Quote
Specifications
Housing Material:
Stainless Steel
Clamp Needle Material:
Aluminum Alloy
Model:
PX-SGA-P
Product Type:
Fixed And Mobile Static Grounding Alarm
Alarm Type:
Audible And Visual Alarm
Cable Configuration:
Fixed 5 M Tank Cable And 3 M Ground Cable Mobile 5 M Tank Cable And 5 M Ground Cable
Product Description
Static Grounding Alarm Fixed Mobile Stainless Steel Housing
Product Overview

The static grounding alarm is an industrial grounding monitoring device designed to help verify electrical grounding connections in dust collection systems, industrial dust extraction pipelines, tanker loading operations, and other static-sensitive environments. Also known as a static grounding monitor or grounding alarm, it helps operators identify an incomplete or abnormal grounding connection during equipment operation and material transfer.

Featuring a stainless steel protective housing and an aluminum alloy paint-piercing clamp needle, the device is designed to establish electrical contact with suitable metal surfaces through appropriate surface coatings. Audible and visual alarms alert operators when the monitored grounding circuit fails to meet the device's operating criteria.

Two configurations are available: a fixed grounding alarm for designated installation points and a mobile grounding monitor for use across multiple work areas. The fixed version uses a single clamp, while the mobile version features a dual-clamp design. For industrial equipment manufacturers, factory operators, EPC contractors, and safety equipment distributors, this device supports more consistent grounding checks. Actual suitability depends on the installation, electrical requirements, and applicable hazardous-area certification.

Cause: Why Grounding Problems Occur

Static electricity can accumulate during powder conveying, pneumatic dust extraction, liquid transfer, and vehicle loading. In industrial dust collectors and metal ducting systems, unsuitable bonding or grounding connections may allow electrical charge to accumulate on conductive components.

Common problems include loose grounding cables, corroded contact points, clamps attached to painted surfaces, and connections that are not checked consistently. Conventional grounding clamps do not necessarily monitor the complete circuit or alert operators when a connection becomes ineffective.

In facilities handling combustible dust or flammable liquids, these issues require careful risk assessment. A reliable grounding monitoring procedure helps operators identify connection faults and improve the consistency of site safety practices.

Solution: Monitored Grounding for Industrial Operations

The static grounding alarm monitors its grounding circuit and provides audible and visual warnings when a detected fault meets the configured alarm conditions. Its paint-piercing clamp needle is designed to improve contact with suitable metal surfaces, while the stainless steel housing provides a protective enclosure for industrial use.

The fixed version suits a designated installation point, while the mobile version can be moved between work areas. Standard cable configurations support different installation layouts.

When incorporated into an appropriate operating procedure, the device helps improve grounding checks for industrial dust collection equipment, metal ducting, and material transfer operations. It should be used alongside suitable bonding, grounding, equipment maintenance, and site-specific hazard controls. It does not eliminate every electrostatic ignition risk.

Specifications
Parameter Specification
Model PX-SGA-P
Product Type Fixed or mobile static grounding alarm
Power Supply Lithium battery; dry battery option subject to confirmation
Fixed Configuration Single clamp
Fixed Tank Cable 5 m; Custom
Fixed Ground Cable 3 m; Custom
Mobile Configuration Dual clamps
Mobile Tank Cable 5 m; Custom
Mobile Ground Cable 5 m; Custom
Housing Material Stainless steel protective shell
Clamp Needle Material Aluminum alloy
Alarm Type Audible and visual
Main Function Grounding circuit monitoring
Application Industrial dust collection, metal ducting, tanker loading, and chemical handling

Confirm the grounding resistance threshold, battery specifications, cable options, and hazardous-area certification for the selected model before ordering.

Application
  • Industrial dust collectors and dust extraction pipelines: Support grounding checks for suitable conductive dust collection equipment and metal ducting where static control is required. Confirm system compatibility and grounding design before installation.

  • Industrial ventilation and powder handling: Support grounding procedures for compatible conductive equipment used in dust extraction and material conveying.

  • Tank truck loading stations: Check grounding connections before and during suitable liquid transfer operations.

  • Fuel depots and terminals: Support grounding checks during tanker loading and unloading.

  • Chemical plants: Monitor grounding connections during solvent and compatible flammable-liquid handling.

  • Paint and solvent storage facilities: Support electrostatic risk-control procedures in designated transfer areas.

  • EPC projects and safety equipment distribution: Supply suitable fixed or mobile grounding monitoring configurations for industrial sites.

Actual suitability depends on the materials handled, equipment design, hazardous-area classification, and applicable local regulations.

How It Works

The operator attaches the clamp to an appropriate metal contact point and connects the grounding lead according to the installation instructions. The paint-piercing needle is designed to penetrate suitable coatings and improve electrical contact.

The monitor checks the grounding circuit against its configured operating criteria. If a disconnection or unacceptable circuit condition is detected, the audible and visual alarm alerts the operator.

For industrial dust collectors and conductive ducting, the device must be incorporated into a properly engineered grounding and bonding arrangement. It is not a substitute for verifying the electrical continuity of the complete dust collection system. Automatic equipment shutdown is possible only when a compatible, verified interlock is included.

How To Choose

Step 1: Identify the application. Confirm whether the device will be used with a dust collector, conductive ductwork, a tanker loading bay, or another installation.

Step 2: Select the configuration. Choose the fixed type for a designated point or the mobile type for use across multiple locations.

Step 3: Check cable lengths. Standard configurations use a 5 m tank cable, with a 3 m ground cable for the fixed type and a 5 m ground cable for the mobile type.

Step 4: Verify electrical and grounding requirements. Confirm the grounding arrangement, alarm threshold, power supply, and any required integration with the site's control system.

Step 5: Confirm hazardous-area suitability. Request the relevant certification and complete protection marking if the device will be installed in a classified hazardous area.

Contact our team with your application, cable requirements, installation environment, and certification needs for product selection and a quotation.

FAQ

1. Can the static grounding alarm be used with industrial dust collectors and dust extraction pipelines?

It may be suitable for grounding monitoring in compatible conductive equipment and metal ducting. The installation must be checked against the system's grounding design and the device's specifications.

2. What is a static grounding alarm?

It is a monitoring device that checks a grounding circuit and alerts operators when a monitored connection fault is detected.

3. What is the difference between fixed and mobile types?

The fixed type is intended for a designated installation point. The mobile type is designed to move between work areas and uses a dual-clamp configuration.

4. Can the clamp connect through paint or rust?

The paint-piercing needle is designed to penetrate suitable surface coatings. The contact point must still be appropriate and the connection must meet the manufacturer's installation requirements.

5. Does the alarm automatically stop equipment operation?

Not necessarily. Automatic shutdown requires a compatible interlock system. Without one, operators must follow the site's stop-work procedure when an alarm occurs.

6. Is the device certified for explosive atmospheres?

Certification must be verified for the exact model and intended hazardous area. Request the applicable certificate and protection marking before installation.

7. Can cable lengths be customized?

The listed standard lengths are 5 m plus 3 m for the fixed type and 5 m plus 5 m for the mobile type. Confirm longer cable options with the supplier.

Related Products
Send An Inquiry